15kv High Voltage Pin Post Composite Insulator Manufacture

15kv High Voltage Pin Post Composite Insulator Manufacture

The insulators are constructed on a fibre glass core rod with a one-piece EPDMor silicone rubber sheath/weather shield.

Product Introduction

Our service objective is to provide quality 10kV Composite Long Rod Insulator, Composite horizontal line post insulator, Composite Tension Insulator and services in a timely manner according to our customers' requirements. The company adheres to a global layout and innovation-driven strategy to provide customers with simpler, more agile and safer products and solutions. Our business activities and processes are engineered to make sure our customers have access to widest range of products with the shortest supply time lines.

Line Post Pin Insulators

4(001) 

1. Line post pin insulator technical data

System Voltage
(kV)

Height
(mm)

Dry Arcing Distance
(mm)

Creepage Distance
(mm)

Specified Cantilever Load 
(SCL)

Max. Design Cantilever Load 
(MDCL)

Power Frequency Withstand Voltage
(kV)

Lightning Impulse Withstand Voltage
(kV)

15

265±10

180

400

5kN

2.5kN

47

105

 

2. 15kV composite post insulators crimping

  • Line post pin insulators are made of the fibre glass core rod coverd with silicone rubber by high temperature vulcanization whole injection.

  • The end fillings are compression crimped to the core and sheath to ensure a weatherproof seal. 

1(003)

 3(001)


3. Marking

Each insulator unit is marked with the name or trade mark of the manufacturer, the year of manufacture, the specified mechanical failing load and serial no. in accordance with IEC 61952 and means to ensure a system of trace-ability for each of the component parts. 

5(001)(001)


4. Packing and Transportation

Insulator units shall be packed in plywood cases or solid wood cases. The packing shall afford adequate protection for the insulators during handling and shipping. 

We can provide CO (Original Certificates) if client need.


5. Composite Post Insulator's installation, storing and transportation

1)When the Composite Post Insulator with the base is installed, the base and insulator are bolted together with bolts firstly and then fixed integrally on the mounting rack.

2)Before installation, the goods should stored in dry warehouse. It should not expose to oil and petrifaction products, and should take actions to keep away from rats.

3)During transportation, hardware fittings and other heavy objects shouldn't be stacked on the insulators directly to avoid damaging the insulator's sheath. So it should be unpacked only at the installation site.

4)Be careful and avoid edge tools cutting the insulator's sheds when unpacking the Box.

5)Don't drag the insulators on the ground.

6)Be careful not to bend the insulator too much, which avoid the excessive bending stress of insulators' rod.

7)The rope should be attached to the end-fitting rather than hang it on the insulator's sheds directly when in hanging installation.

8)Don't treading and climbing on insulators.

 


Our growth depends on the superior equipment, exceptional talents and continuously strengthened technology forces for 15kv High Voltage Pin Post Composite Insulator Manufacture. Our company will strictly abide by the promise, actively forge ahead, further increase research and development investment, develop better products to share with users, and wholeheartedly provide the best service for them. Through continuous innovation and reform, our professional service team integrating 'planning, design, production, packaging and distribution' has been created.