Through our continuous efforts, our Polymer Deadend Insulator, 33kv Post Insulator Drawing, Bases For Insulators breaks through the technical limitations of the industry and become a new benchmark for innovation. Our team is made up of individuals who are passionate about their work and dedicated to delivering the best possible results. The company creates an innovative environment, empowers team members to accept new ideas to promote business growth, encourages teamwork, and believes that synergy can bring the best results to customers and the whole company.
Line Post Pin Insulators

1. Line post pin insulator technical data
System Voltage | Height | Dry Arcing Distance | Creepage Distance | Specified Cantilever Load | Max. Design Cantilever Load | Power Frequency Withstand Voltage | Lightning Impulse Withstand Voltage |
15 | 265±10 | 180 | 400 | 5kN | 2.5kN | 47 | 105 |
2. 15kV composite post insulators crimping
Line post pin insulators are made of the fibre glass core rod coverd with silicone rubber by high temperature vulcanization whole injection.
The end fillings are compression crimped to the core and sheath to ensure a weatherproof seal.


3. Marking
Each insulator unit is marked with the name or trade mark of the manufacturer, the year of manufacture, the specified mechanical failing load and serial no. in accordance with IEC 61952 and means to ensure a system of trace-ability for each of the component parts.

4. Packing and Transportation
Insulator units shall be packed in plywood cases or solid wood cases. The packing shall afford adequate protection for the insulators during handling and shipping.
We can provide CO (Original Certificates) if client need.
5. Composite Post Insulator's installation, storing and transportation
1)When the Composite Post Insulator with the base is installed, the base and insulator are bolted together with bolts firstly and then fixed integrally on the mounting rack.
2)Before installation, the goods should stored in dry warehouse. It should not expose to oil and petrifaction products, and should take actions to keep away from rats.
3)During transportation, hardware fittings and other heavy objects shouldn't be stacked on the insulators directly to avoid damaging the insulator's sheath. So it should be unpacked only at the installation site.
4)Be careful and avoid edge tools cutting the insulator's sheds when unpacking the Box.
5)Don't drag the insulators on the ground.
6)Be careful not to bend the insulator too much, which avoid the excessive bending stress of insulators' rod.
7)The rope should be attached to the end-fitting rather than hang it on the insulator's sheds directly when in hanging installation.
8)Don't treading and climbing on insulators.

We strive for excellence, services the customers', hopes to be the top cooperation team and dominator business for personnel, suppliers and prospects, realizes benefit share and continual promotion for 15kv Post Insulator. We will wholeheartedly provide customers with all support and guarantees other than non-core business. In order to adapt to the market economy, we keeps up with the pace of the times and continues to provide users with the best products and services with the tenet of 'innovation, standardization and quality'.
Hot Tags: Line post pin insulators, China, manufacturers, suppliers, factory, wholesale, for sale, Polymer Station Post Insulators, Composite Post Insulators For Railway, 400kV Composite Long Rod Insulator, 11kv Polymer Pin Insulator, Composite Suspension Insulator, 10kV Pin Insulators