Our company produces and sells each 138kV Composite Line Post Insulator, Composite Insulator Rubber, 11kv Post Insulator through the professional instrument's precision inspection, the product has the reliable quality assurance. In order to fully meet the needs of society as well as our customers, we must grow bigger and stronger as a company. Our pursuit of excellence requires not only technological innovation, but also simultaneous transcendence in products, markets, management, systems and concepts. Our new, open and international management enables the performance and quality of our products to be continuously improved, and we strive to provide each customer with quality solutions and personalized services.
Wuhan Line Power Transmission and Transformation Co., Ltd. specializes in the production and sale of composite insulators and accessories. As a manufacturing company integrating production, processing, and distribution, we focus on the R&D, manufacturing, and sales of complete sets of composite insulator equipment. With high-quality products, competitive prices, and excellent service, we have earned the trust and praise of customers worldwide.
Our factory is equipped with the most advanced Automatic Silicone Injection Molding Machines and Voice-operated Displacement Crimping Machines, representing the highest level of process technology. We also have 1000 kV Power Frequency Testing Transformers, 1800 kV Impulse Voltage Generator Sets, and 2000 kN Automatic Tensile Test Machines, along with fully equipped Physical and Electrical Laboratories.
We design products according to client requirements and strictly follow international quality standards including IEC 61109, ISO 9001, ISO 14001, and ISO 45001. Our strict quality management system ensures all products meet IEC61109, IEC62231, GB/T19519-2004, GE/T 22079-2005, DL/T810-2002, and other relevant standards.

Technical Drawings & Dimensions
Our composite insulators are made of a glass fiber epoxy core rod, silicone rubber sheds, and metal fittings. The silicone sheds use a full-pressure technique, which solves a key problem – electric spark punctures at the interface – so the insulator stays reliable. The glass fiber rod is connected to the metal fittings with advanced crimping technology, and we have a full automatic ultrasonic system to check for defects. They are strong, compact, lightweight, and look nice. The metal fittings are galvanized to prevent corrosion. Compared with porcelain insulators, they are reliable, make full use of the core rod's strength, and are easier to handle without damage.

| Parameter | Value |
| Rated Voltage | 500 kV |
| Height | 4030 ± 50 mm |
| Specified Mechanical Load (SML) | 70 kN |
| Routine Test Load (RTL) | 35 kN |
| Rod | 24 mm |
| Creepage Distance | 13000 mm |
| Dry Arcing Distance | 3730 mm |
| Lightning Impulse Withstand Voltage | ≥ 2050 kV |
| Switching Impulse Withstand Voltage | ≥ 1240 kV |
| Wet Power Frequency Withstand Voltage (1 min) | ≥ 740 kV |
| Product Standard | IEC 61109 |
| Housing Material | Silicone Rubber |
| Color | Red |
| No. of Sheds | 153 |
packing & Shipping photos
Each container is carefully loaded with our 500kV composite insulators to ensure safe transportation. For example, a standard 40-foot high-cube container can accommodate up to 660 insulators. The insulators are securely packaged, and we always ensure that the packaging effectively protects the products during shipping and handling.

Certifications & Compliance

Wuhan Line power is always pursuing the principle of Quality First and Customers Supreme. Our product has been subjected the test in accordance with IEC 61109-2008, some of the test items are as follows:
Design tests
Tests on interfaces and connections of end fittings
• Pre-stressing – Sudden load release pre-stressing
• Thermal-mechanical pre-stressing
• Water immersion pre-stressing
• Steep-front impulse voltage test
• Dry power-frequency voltage test
Tests on shed and housing material
• Hardness test
• Accelerated weathering test
• Tracking and erosion test
• Flammability test
Tests on the core material
• Dye penetration test
• Water diffusion test
Assembled core load-time test
• Determination of the average failing load of the core of the assembled insulator
• Control of the slope of the strength-time curve of the insulator
Type tests
• Dry lightning impulse withstand voltage test
• Wet power frequency test
• Wet switching impulse withstand voltage test for insulators intended for systems with Um≥300 kV
Sample tests
• Verification of dimensions
• Verification of the end fittings
• Verification of tightness of the inter face between end fittings and insulator housing and of the specified mechanical load, SML
• Galvanizing test
Routine tests
• Mechanical routine test
• Visual examination
Production Equipment
The company owns state-of-the-art Automatic Silicone Injection Molding Machines and Voice-Controlled Displacement Crimping Machines, representing the highest level of process technology in the world.
We are also equipped with a 1000 kV Power Frequency Test Transformer, an 1800 kV Impulse Voltage Generator, and a 2000 kN Automatic Tensile Testing Machine, supported by fully equipped Physical and Electrical Laboratories.

Nowadays, we have been seeking our best to become certainly one of the most effective exporters in our discipline to meet shoppers more require for (FXBW4-24/100) Long Rod Suspension Composite Insulators. In the future, our responsibilities will become more important, and at the same time we will open a new chapter in the company's development path. We always give back to consumers with advanced technology and excellent quality.
Hot Tags: 500kV 120kN Composite Polymeric Suspension Rod Insulator, China, manufacturers, suppliers, factory, wholesale, for sale, 11kv Post Insulator, HDPE Pin Insulators, 15kV Composite Post Insulators, 110kV Composite Suspension Insulator, 33kv polymer disc insulator, Composite Suspension Insulators For Railway