110kv Composite Station Post Insulator

110kv Composite Station Post Insulator

In the early years, station post insulators were mostly used for telegraph poles. With the development of science and technology, a lot of disc-shaped insulators were hung at one end of the high-type high-voltage line connection tower, which was to increase the creepage distance.

Product Introduction

Good quality comes to start with; service is foremost; organization is cooperation' is our enterprise philosophy which is regularly observed and pursued by our firm for 25kV Composite Post Insulators, Spare Parts For Composite Insulators, 11kv Polymer Pin Insulator . We know that the development of enterprises cannot be separated from the support of talents and science and technology, so we strengthen the cooperation with universities to complement each other's advantages. We believe in the power of collaboration and community, working together with our partners to drive innovation and success. Our team of experts has extensive experience in navigating the complex and constantly evolving landscape of international trade, ensuring that our clients’ shipments are always handled in full compliance with local laws and regulations. The company will persevere, continue to innovate, and join hands with new and old customers to create brilliant!

110kV 17.2kN Composite Station Post Insulator

 

 

Products Description

 

Model

Rated
Votage

Specified Cantilever Load(SCL)

Maximum Design Cantilever Load(MDCL)

Routine Tensile Test Load(RTL)

Power Frequency Withstand Voltage(Dry/Wet)

Lightning Impulse Withstand Voltage

(kV)

(kN)

(kN)

(kN)

(kV)

≥(kV)

FZSW-110/17.2

110

17.2kN

7.7kN

16.5

315kV/275kV

570kV

 

Features:

1. Perform excellent anti-pollution capacity and explosion proof.

2. New type insulating materials for inner insulation and high tempreture sulfarated silicone rubber for outer insulation

3. They are consistent with current developing trend of requiring no oil and miniaturization by electricity sector.

 

 

knowledge

 

Post insulators used for busbars or disconnectors are typical examples of station post insulators applied in power plants to provide insulation and a mechanically secured connection between conductors and grounded structures. They are assembled by bonding solid porcelain columns with upper and lower metal fittings using cement adhesive. Because the flashover distance along the outer air path is nearly the same as the internal creepage path, flashover occurs externally, and internal dielectric breakdown of the porcelain-being a non-puncture-type material-does not take place. For higher voltage levels, multiple post insulator units can be connected in series. To enhance mechanical strength, several post insulators may also be installed in parallel when required. These insulators are capable of bearing bending moments and torsional forces.

 

In recent years, China has developed a composite station post insulator that uses a porcelain core combined with a silicone rubber housing. This design provides better electrical and mechanical performance compared with traditional porcelain station post insulators. Silicone rubber offers higher mechanical strength and improved resistance to pollution flashover, giving the composite type substantial potential for broader application.

A variety of factors-such as electric field strength, mechanical loads, environmental stresses, and climatic conditions-affect the performance of outdoor insulators during operation. These factors act simultaneously, and their influence varies depending on the insulator's type, structure, and installation environment. For example, suspension and tension insulators must bear the tensile load of the conductor as well as their own weight. Additional tensile forces may arise due to strong winds, icing, or temperature variations. Station post insulators, on the other hand, are subjected primarily to compressive forces, along with bending moments and torsional loads.

 

When evaluating the mechanical forces on station post insulators, both the static load from supported busbars and equipment, as well as electromagnetic forces generated under fault conditions, must be considered. Cantilever-type cross-arm insulators also experience bending moments from conductor loads. Insulators may be exposed to various transient forces, including torsional loads during transmission-line construction and vibration loads caused by conductor swing. In service, they must also withstand impact loads from natural or accidental sources such as storms, earthquakes, or the sudden drop of ice-covered conductors.

 

Electrically, insulators must tolerate not only steady-state power-frequency voltage but also transient overvoltages caused by lightning or switching operations. All three voltage types must be considered when determining the required insulator string length or dry arcing distance. In general, lightning overvoltage is the primary factor influencing dry arc distance below 330 kV, whereas switching overvoltage becomes dominant above 330 kV. During flashover, several thousand amperes of fault current may flow along the insulator surface in the form of an arc. The insulator must be capable of withstanding the thermal and physical damage of this arc until the protection system isolates the fault.

 

 

about us

Profile of Wuhan Line Power, Polymer Insulators (3)_07

 

 

Adhering for the theory of 'quality, services, performance and growth', we have received trusts and praises from domestic and worldwide shopper for 110kv Composite Station Post Insulator. Over the years, we have provided services to major enterprises, able to predict problems in time and provide effective solutions for customers. We now have established long-term and successful cooperative relationships with many customers through their confidence in our customized services and integrity in doing business.

Hot Tags: 110kV 17.2kN Composite Station Post Insulator, China, manufacturers, suppliers, factory, wholesale, for sale, Tension insulators, Composite polymer insulator, pin post insulator, 10kV Pin Insulators, insulator line post, 15kV Composite Deadend insulators