Our company sticks into the basic principle of 'Quality is definitely the life of the business, and status may be the soul of it' for 10kV composite polymer pin insulator, 69kV Composite Station Post Insulator, Silicone Rubber Tension Insulator . We take the core of the corporate culture of looking into the overall situation, seeking truth and being pragmatic as the connotation, and uphold the spirit of dare to take responsibility and dare to be responsible. We not only provide standard products, but also provide customization with special specifications, just to provide better customer experience. The company is committed to providing technical products and professional services to the industry and making greater contributions to the development of the industry. Our team of experts has a wealth of experience in the industry and is passionate about delivering excellence.
Post Insulators 16kN With Top And Bottom Flange.
Detailed Description
|
Rated Voltage: |
72.5kV |
SCL: |
16kN |
|
Type: |
Station Post |
Type Test: |
Provide |
|
Material: |
Composite, Polymer |
Sample Available: |
Yes |
Reasonable Design and Excellent material
|
End Fittings |
Core |
Sheds and Housing |
|
Materials: Hot dip galvanized cast iron or cast steel |
Epoxy & Glass Fiber |
HTV Silicone Rubber |
|
Min. thickness of the galvanization: 86μm |
Rod Diameter: Φ70mm |
Color: Gray,Red |

Technical Data
|
Rated Voltage |
Height |
Dry Arcing Distance |
Creepage Distance |
Specified Cantilever Load |
Max. Design Cantilever Load |
Max. Design Torsion Load |
Dry Power Frequency Withstand Voltage |
Lightning Impulse Withstand Voltage |
|
72.5 |
770±1 |
682mm |
1813 |
16kN |
10kN |
1.2kN • m |
165 |
325 |
Post Insulators Inspection and Testing
1.1Type Tests
The following type tests as per the relevant standard shall be conducted on the Insulators of identical design to prove that the offered insulator satisfies all the design requirements set out in this specification.
(i)Verification of the dimensions
(ii)Mechanical failing load
(iii)Thermal-mechanical performance test
(iv)Dry lightning impulse withstand voltage test
(v)Wet Power-frequency withstand voltage test
1.2Routine Tests
The manufacturer shall carry out, at his own expense, the routine tests; specified in IEC 60383. The routine tensile load shall be 50% of the electromechanical failing load.
(i)Routine visual inspection
(ii)Routine mechanical test
(iii)Routine electrical test
1.3Acceptance Tests
(i)Verification of the dimensions
(ii)Mechanical failing load test

Marking
Each Post Insulators unit is marked with the name or trade mark of the manufacturer and the year of manufacture in accordance with IEC 61952 and means to ensure a system of trace-ability for each of the component parts. In addition, each insulator unit is marked with the specified mechanical failing load in conformity with lEC 61952 and client' requirements.
Package and Transportation
Insulator units shall be packed in plywood cases or solid wood cases. The packing shall afford adequate protection for the insulators during handling and shipping. We can provide CO(Original Certificates) if client need.
Our advantages are lessen charges, dynamic income team, specialized QC, sturdy factories, premium quality services for Fzsw-66/8 66kv Station Post Composite Insulator, Post Insulator. We will strengthen the coverage and management of different sales areas. We will establish a more complete mechanism, actively assume responsibility, and formulate procedures that can be implemented steadily to ensure our company can grow steadily.
Hot Tags: 72.5kV,16kN Post Insulators with Top and Bottom Flange 72.5kV, China, manufacturers, suppliers, factory, wholesale, for sale, post insulator and pin insulator, 66kV Composite Long Rod Insulator, Composite Long Rod Insulator, 132kv Post Insulator, 25kV Composite Deadend insulators, 33kV composite polymer pin insulator