Polymer Line Post Insulators for 15kv to 230kv Applications

Polymer Line Post Insulators for 15kv to 230kv Applications

The insulators are constructed on a fibre glass core rod with a one-piece EPDMor silicone rubber sheath/weather shield.

Product Introduction

Our 45kV composite polymer pin insulator, 138kV Composite Line Post Insulator, Horizontal Post Insulator are new in style and fashionable in design. We do every product with our heart and focus on the production and manufacture of products.We have extraordinary production supply chain, we have massive inventory, and many years of processing experience. We have a cooperative technical team and a perfect after-sales service system. Through the introduction of management and technology and the establishment of staff training system, we constantly improve the ability of internal management and customer service.

Line Post Pin Insulators

4(001) 

1. Line post pin insulator technical data

System Voltage
(kV)

Height
(mm)

Dry Arcing Distance
(mm)

Creepage Distance
(mm)

Specified Cantilever Load 
(SCL)

Max. Design Cantilever Load 
(MDCL)

Power Frequency Withstand Voltage
(kV)

Lightning Impulse Withstand Voltage
(kV)

15

265±10

180

400

5kN

2.5kN

47

105

 

2. 15kV composite post insulators crimping

  • Line post pin insulators are made of the fibre glass core rod coverd with silicone rubber by high temperature vulcanization whole injection.

  • The end fillings are compression crimped to the core and sheath to ensure a weatherproof seal. 

1(003)

 3(001)


3. Marking

Each insulator unit is marked with the name or trade mark of the manufacturer, the year of manufacture, the specified mechanical failing load and serial no. in accordance with IEC 61952 and means to ensure a system of trace-ability for each of the component parts. 

5(001)(001)


4. Packing and Transportation

Insulator units shall be packed in plywood cases or solid wood cases. The packing shall afford adequate protection for the insulators during handling and shipping. 

We can provide CO (Original Certificates) if client need.


5. Composite Post Insulator's installation, storing and transportation

1)When the Composite Post Insulator with the base is installed, the base and insulator are bolted together with bolts firstly and then fixed integrally on the mounting rack.

2)Before installation, the goods should stored in dry warehouse. It should not expose to oil and petrifaction products, and should take actions to keep away from rats.

3)During transportation, hardware fittings and other heavy objects shouldn't be stacked on the insulators directly to avoid damaging the insulator's sheath. So it should be unpacked only at the installation site.

4)Be careful and avoid edge tools cutting the insulator's sheds when unpacking the Box.

5)Don't drag the insulators on the ground.

6)Be careful not to bend the insulator too much, which avoid the excessive bending stress of insulators' rod.

7)The rope should be attached to the end-fitting rather than hang it on the insulator's sheds directly when in hanging installation.

8)Don't treading and climbing on insulators.

 


Details determine success or failure, professional manufacturing achieves excellent quality. We regard quality as life, pursue 100% product qualification rate, and strive to provide customers with the most excellent Polymer Line Post Insulators for 15kv to 230kv Applications and services. We're seeking forward for your inquiries. Over the years, we have established a stable supply relationship with many merchants by virtue of advanced technology, excellent quality and good reputation.