video
Line Post Composite Insulator 275kV with Flang and Drop Tongue

Line Post Composite Insulator 275kV with Flang and Drop Tongue

Rated voltage: 275kV
Port of departure: Shanghai port
HS Code: 854690
Test report: Yes Lead time: 30-60 days ex-works

Product Introduction

Line Post Composite Insulator

  1. Line post composite insulator catalog and technical datas

    TypeRated voltage (kV)Mechnicla load (kN)Length (mm)Nominal creepage distance (mm)Insulation distance (mm)Wet withstand voltage (kV)Lightning impluse withstand voltage (kV)
    FZSW-66/12.56612.51030±302410744140 (Flashover)330
    FZSW-69/136913865±20191062445 (Flashover)208 (Critical impulse flashover voltage)
    FZSW-69/136913866±20190061445 (Flashover)208 (Critical impulse flashover voltage)
    FZSW-66/20.66620.61006±152420754265 (Flashover)670 (Critical impulse flashover voltage)
    FZSW-66/20.66620.61040±202410744210420
    FZSW-66/12.56612.5860±201920635200 (Flashover)450 (Critical impulse flashover voltage)
    FZSW-138/613861506±304060125391 (Flashover)364 (Flashover)
    FZSW-138/613861510±204070127091 (Flashover)364 (Critical impulse flashover voltage)
    FZSW-138/913891810±3049201543450 (Flashover)1034 (Critical impulse flashover voltage)
    FZSW-138/13138131588±1542901336405 (Flashover)805 (Critical impulse flashover voltage)
    FZSW-132/14.513214.51230±152990945350555
    FZSW-132/14.313214.31506±1540701263430 (Flashover)815 (Critical impulse flashover voltage)
    FZSW-132/14.613214.61496±1040601253

    FZSW-132/15.1132151415±1037801171370640
    FZSW-115/16115161342±1534801052365 (Flashover)665 (Critical impulse flashover voltage)
    FZSW-132/17.513217.51274±303230995275560
    FZSW-132/17.913217.91255±303030983275560
    FZSW-275/627562979±30895027276101330
    FZSW-220/922092125±30624019124801030
    FZSW-145/414541515±3040501246275650
    FZSW-362/436243000±3090102787950 (Wet operating impluse withstand)1300
  2. knowledge
  3.  

  4. For the reconstruction of old lines, we recommend the selection of composite insulators according to the following principles.

  5. As far as possible to choose the structure height of the composite insulator.

  6. For the structure height of 1240mm and the following composite insulators, the probability of a variety of flashover is relatively high, some of the power sector has put forward to strengthen the height of the composite insulators requirements, Shandong Power Company in 1995 on the following requirements of the various branches of the electric power to choose the structure height of 1440mm 110kV composite insulators, over the past few years, such insulators are seldom flashover.

  7. Altitude of more than 1000m above sea level, the structure height should be longer, high-altitude areas, especially in areas with seasonal water sources, the next season is the south of the large migratory birds inhabiting the place, and in winter is a large migratory birds from Siberia, the use of structural height of 1350mm composite insulators, there is no effective anti-bird measures, the occurrence of the "unknown" (bird damage) flashover probability will be very high. The probability of flashover is very high.


  8. Product photos

Line post composite insulator 2

Line post composite insulator 3Line post composite insulator 4

Hot Tags: Line Post Composite Insulator 275kV with Flang and Drop Tongue, China, manufacturers, suppliers, factory, wholesale, for sale, 132kv Post Insulator, Composite Braced Line post Insulator, Polymer Line Post Insulators, Vertical Line Post insulator, 11kv Post Insulator, insulator line post

Send Inquiry

whatsapp

teams

E-mail

Inquiry

Bag