Line Post Composite Insulator
Line post composite insulator catalog and technical datas
Type Rated voltage (kV) Mechnicla load (kN) Length (mm) Nominal creepage distance (mm) Insulation distance (mm) Wet withstand voltage (kV) Lightning impluse withstand voltage (kV) FZSW-66/12.5 66 12.5 1030±30 2410 744 140 (Flashover) 330 FZSW-69/13 69 13 865±20 1910 624 45 (Flashover) 208 (Critical impulse flashover voltage) FZSW-69/13 69 13 866±20 1900 614 45 (Flashover) 208 (Critical impulse flashover voltage) FZSW-66/20.6 66 20.6 1006±15 2420 754 265 (Flashover) 670 (Critical impulse flashover voltage) FZSW-66/20.6 66 20.6 1040±20 2410 744 210 420 FZSW-66/12.5 66 12.5 860±20 1920 635 200 (Flashover) 450 (Critical impulse flashover voltage) FZSW-138/6 138 6 1506±30 4060 1253 91 (Flashover) 364 (Flashover) FZSW-138/6 138 6 1510±20 4070 1270 91 (Flashover) 364 (Critical impulse flashover voltage) FZSW-138/9 138 9 1810±30 4920 1543 450 (Flashover) 1034 (Critical impulse flashover voltage) FZSW-138/13 138 13 1588±15 4290 1336 405 (Flashover) 805 (Critical impulse flashover voltage) FZSW-132/14.5 132 14.5 1230±15 2990 945 350 555 FZSW-132/14.3 132 14.3 1506±15 4070 1263 430 (Flashover) 815 (Critical impulse flashover voltage) FZSW-132/14.6 132 14.6 1496±10 4060 1253 FZSW-132/15.1 132 15 1415±10 3780 1171 370 640 FZSW-115/16 115 16 1342±15 3480 1052 365 (Flashover) 665 (Critical impulse flashover voltage) FZSW-132/17.5 132 17.5 1274±30 3230 995 275 560 FZSW-132/17.9 132 17.9 1255±30 3030 983 275 560 FZSW-275/6 275 6 2979±30 8950 2727 610 1330 FZSW-220/9 220 9 2125±30 6240 1912 480 1030 FZSW-145/4 145 4 1515±30 4050 1246 275 650 FZSW-362/4 362 4 3000±30 9010 2787 950 (Wet operating impluse withstand) 1300 knowledge
For the reconstruction of old lines, we recommend the selection of composite insulators according to the following principles.
As far as possible to choose the structure height of the composite insulator.
For the structure height of 1240mm and the following composite insulators, the probability of a variety of flashover is relatively high, some of the power sector has put forward to strengthen the height of the composite insulators requirements, Shandong Power Company in 1995 on the following requirements of the various branches of the electric power to choose the structure height of 1440mm 110kV composite insulators, over the past few years, such insulators are seldom flashover.
Altitude of more than 1000m above sea level, the structure height should be longer, high-altitude areas, especially in areas with seasonal water sources, the next season is the south of the large migratory birds inhabiting the place, and in winter is a large migratory birds from Siberia, the use of structural height of 1350mm composite insulators, there is no effective anti-bird measures, the occurrence of the "unknown" (bird damage) flashover probability will be very high. The probability of flashover is very high.
Product photos



Hot Tags: Line Post Composite Insulator 275kV with Flang and Drop Tongue, China, manufacturers, suppliers, factory, wholesale, for sale, 132kv Post Insulator, Composite Braced Line post Insulator, Polymer Line Post Insulators, Vertical Line Post insulator, 11kv Post Insulator, insulator line post