Braced Post Swivel Base Assembly Insulator High Voltage Power Transmission

Braced Post Swivel Base Assembly Insulator High Voltage Power Transmission

Products Description List Of Materials Standard Strength Braced Posts 2.5" Line Post Insulator (1 each) 25klb (S199) Suspension Insulator (1 each) ASH-55 Anchor Shackle (2 each) High Strength Braced Posts [marked "HS"] 2.5" Line Post Insulator (1 each) 36klb (S699) Suspension Insulator (1 each)...

Product Introduction
Products Description


1671066039878

Fig.PSLSSLHACB

in (mm)in (mm)in (mm)in (mm)Deg.in (mm)
154.0
(1372)
52.0
(1321)
51.0
(1295)
18.0
(457)
57˚57.5
(1461)
260.0
(1524)
58.0
(1473)
56.0
(1422)
20.0
(508)
57˚63.5
(1613)
366.0
(1676)
64.0
(1626)
61.0
(1549)
22.0
(559)
57˚69.5
(1765)
472.0
(1829)
70.0
(1778)
66.0
(1676)
24.0
(610)
56˚75.5
(1918)
587.0
(2210)
87.0
(2210)
80.0
(2032)
28.0
(711)
56˚92.5
(2350)
693.0
(2362)
93.0
(2362)
85.0
(2159)
30.0
(762)
56˚98.5
(2502)


List Of Materials

Standard Strength Braced Posts

  1. 2.5" Line Post Insulator (1 each)
  2. 25klb (S199) Suspension Insulator (1 each)
  3. ASH-55 Anchor Shackle (2 each)

High Strength Braced Posts [marked "HS"]

  1. 2.5" Line Post Insulator (1 each)
  2. 36klb (S699) Suspension Insulator (1 each)
  3. ASH-56 Anchor Shackle (2 each)


Fig.Catalog NumberLine VoltageMDCLDry ArcLeakageElectrical Flashover (kV)
Weight
60 HzCIFO
kVlbs (kN)in (mm)in (mm)DryWetPosNeglbs (kg)
1B261054XL99 A11510,538
(46.9)
42.6
(1082)
83.7 (2126)40837870477849.2 (22.3)
B261054XL99 B106.3 (2700)54.0 (24.5)
B261054XL99 C129.0 (3277)59.0 (26.8)
B261054XL99 LHS14,000
(62.3)
42.6
(1082)
82.9 (2106)40837870477850.3 (22.8)
B261054XL99 M106.0 (2692)55.1 (25.0)
B261054XL99 N129.0 (3277)60.1 (27.3)
2B261060XL99 A13810,494
(46.7)
48.6
(1234)
102.7 (2609)46042679885254.4 (24.7)
B261060XL99 B122.0 (3099)28.9 (26.7)
B261060XL99 C149.1 (3787)64.3 (29.2)
B261060XL99 LHS14,000
(62.3)
48.6
(1234)
100.5 (2553)46042679885255.5 (25.2)
B261060XL99 M123.7 (3142)60.0 (27.2)
B261060XL99 N146.9 (3731)65.4 (29.7)
3B261066XL99 A16110,458
(46.5)
54.5
(1384)
112.6 (2860)51347489293757.7 (26.2)
B261066XL99 B139.7 (3548)63.5 (28.8)
B261066XL99 C163.7 (4158)68.8 (31.2)
B261066XL99 LHS14,000
(62.3)
54.5
(1384)
110.4 (2804)51347489293758.8 (26.7)
B261066XL99 M137.5 (3493)64.6 (29.3)
B261066XL99 N164.5 (4178)69.9 (31.7)
4B261072XL99 A16110,427
(46.4)
60.5
(1537)
122.4 (3109)565520986102761.0 (27.7)
B261072XL99 B153.4 (3896)37.2 (30.5)
B261072XL99 C188.2 (4780)74.9 (34.0)
B261072XL99 LHS14,000
(62.3)
60.5
(1537)
120.2 (3053)565520986102762.1 (28.2)
B261072XL99 M151.2 (3840)68.3 (31.0)
B261072XL99 N186.0 (4724)76.0 (34.5)
5B261087XL99 A23010,380
(46.2)
72.2
(1834)
154.9 (3934)665608116119874.2 (33.7)
B261087XL99 B193.6 (4917)82.7 (37.5)
B261087XL99 C228.4 (5801)89.9 (40.8)
B261087XL99 LHS14,000
(62.3)
72.2
(1834)
152.7 (3879)665608116119875.3 (34.2)
B261087XL99 M191.4 (4862)83.8 (38.0)
B261087XL99 N225.5 (5728)91.0 (41.3)
6B261093XL99 A23010,361
(46.1)
78.1
(1984)
163.6 (4155)7166521258128577.5 (35.2)
B261093XL99 B208.9 (5306)87.4 (39.6)
B261093XL99 C245.1 (6226)95.1 (43.1)
B261093XL99 LHS13,577
(60.4)
78.1
(1984)
162.6 (4130)7166521258128578.6 (35.7)
B261093XL99 M208.9 (5306)88.5 (40.1)
B261093XL99 N243.9 (6195)96.2 (43.6)

Notes:

  • MDCL = Max. Design Cantilever Load (Load Curves provided upon request)
  • Electrical Data is derived from the assembly "Strike Distance," without corona rings for 161kV and below. All 230kV Braced Post assemblies supplied with a corona ring (Electrical Values include the corona ring).
  • HS = High Strength design. Brace SML = 36k
  • For Higher Strength or Custom Designs, please complete the Braced Post Request Worksheet at the end of this section and return the competed worksheet to MPS through your local MPS Sales Representative.

Customized Designs include any dimensional changes, strength changes, hardware changes, end fitting changes, gain to flat base changes, etc.


Certifications

1670980352990 (1)

We have implemented advanced management and set up a strict quality management system according 1- 1509001 : 200S. All the products' quality requirements comply with IEC61109, IEC62231, G3/T19519-2004,GE/T 22079-200s, DU/T 1048-2007.DL/T810-2002 and TE/T3199.2-200g Standards, etc


Company Profile


1670902462845 (1)

Wuhan Line Power Transmission Equipment Co., Ltd. is mainly engaged in the research ,development,production and sales of high voltage transmission power composite insulator series products.The core technology comes from the scientific and research institutions such as Wuhan University (originally Wuhan University of Water and Electricity),Hubei Institute of Chemical and Industry and Wuhan High Pressure Research Institution and so on. In order to adapt to the industry development demands,it was reformed in combination with national capital by the scientists and engineers who are in the field of composite insulator.


Now it is restructured as a new modernized enterprise which integrates research ,production, marketing and sales. The company had formed a series of composite insulator mature products at the beginning of its establishment. These products have been widely used in power, railway and other industries for many years.The core team members of company technology, production and management have more than 20 years of working experience in the same industry. The excellent core team ensures the high starting point of the company in technology and products.





Hot Tags: braced post swivel base assembly insulator high voltage power transmission, China, manufacturers, suppliers, factory, wholesale, for sale, 15kV Composite Fuse Cut Body, Composite Stay Insulator, Spare Parts For Composite Insulators, Composite Insulator Rubber, 27kV Composite Fuse Cut Body, 38kV Composite Fuse Cut Body