DC Composite long-rod Insulator(±400KV~±800KV)
| No | Model |
rated voltage KV |
Rated mechanical tensile load KN |
Connected Structure Marker |
Structure height H mm |
Minimum nominal insulation distance H mm |
Minimum nominal creepage distances L mm |
Lightning impulse withstand voltage KV (peak) not less than | Wet operation shock withstand voltage KV (peak) not less than | Industrial frequency wet withstand voltage KV (RMS) not less than |
| 1 | FXBZ-±400/160(180) | ±400 | 160(180) | 20 | 8000±50 | 7600 | 7600 | +2800 | +1800 | +750 |
| 2 | FXBZ-±400/210(240) | ±400 | 210(240) | 20 | 8000±50 | 7600 | 7600 | +2800 | +1800 | +750 |
| 3 | FXBZ-±400/300 | ±400 | 300 | 24 | 8000±50 | 7600 | 7600 | +2800 | +1800 | +750 |
| 4 | FXBZ-±400/400(420) | ±400 | 400(420) | 28 | 8000±50 | 7600 | 7600 | +2800 | +1800 | +750 |
| 5 | FXBZ-±400/530(550) | ±400 | 530(550) | 32 | 8000±50 | 7500 | 7500 | +2250 | +1150 | +600 |
| 6 | FXBZ-±500/160(180) | ±500 | 160(180) | 20 | 5440±50 | 5070 | 5070 | +2250 | +1550 | +600 |
| 7 | FXBZ-±500/210(240) | ±500 | 210(240) | 20 | 5440±50 | 5070 | 5070 | +2250 | +1550 | +600 |
| 8 | FXBZ-±500/300 | ±500 | 300 | 24 | 5440±50 | 5040 | 5040 | +2250 | +1550 | +600 |
| 9 | FXBZ-±500/400(420) | ±500 | 400(420) | 28 | 5440±50 | 4950 | 4950 | +2250 | +1550 | +600 |
| 10 | FXBZ-±500/530(550) | ±500 | 530(550) | 32 | 5440±50 | 4900 | 4900 | +2250 | +1550 | +600 |
| 11 | FXBZ-±500/160(180) | ±500 | 160(180) | 20 | 6000±50 | 5630 | 5630 | +2250 | +1550 | +600 |
| 12 | FXBZ-±500/210(240) | ±500 | 210(240) | 20 | 6000±50 | 5630 | 5630 | +2250 | +1550 | +600 |
| 13 | FXBZ-±500/300 | ±500 | 300 | 24 | 6000±50 | 5600 | 5600 | +2250 | +1550 | +600 |
| 14 | FXBZ-±500/400(420) | ±500 | 400(420) | 28 | 6000±50 | 5510 | 5510 | +2250 | +1550 | +600 |
| 15 | FXBZ-±500/530(550) | ±500 | 530(550) | 32 | 6000±50 | 5500 | 5500 | +2250 | +1550 | +600 |
| 16 | FXBZ-±660/160(180) | ±660 | 160(180) | 20 | 8500±50 | 8100 | 8100 | +2800 | +1800 | +750 |
| 17 | FXBZ-±660/210(240) | ±660 | 210(240) | 20 | 8500±50 | 8100 | 8100 | +2800 | +1800 | +750 |
| 18 | FXBZ-±660/300 | ±660 | 300 | 24 | 8500±50 | 8100 | 8100 | +2800 | +1800 | +750 |
| 19 | FXBZ-±660/400(420) | ±660 | 400(420) | 28 | 8500±50 | 8000 | 8000 | +2800 | +1800 | +750 |
| 20 | FXBZ-±660/530(550) | ±660 | 530(550) | 32 | 8500±50 | 8000 | 8000 | +2800 | +1800 | +750 |
| 21 | FXBZ-±800/160(180) | ±800 | 160(180) | 20 | 11500±50 | 11140 | 11140 | +3600 | +1950 | +900 |
| 22 | FXBZ-±800/160(180) | ±800 | 160(180) | 20 | 11500±50 | 11140 | 11140 | +3600 | +1950 | +900 |
| 23 | FXBZ-±800/300 | ±800 | 300 | 24 | 11500±50 | 11100 | 11100 | +3600 | +1950 | +900 |
| 24 | FXBZ-±800/400(420) | ±800 | 400(420) | 28 | 11500±50 | 11000 | 11000 | +3600 | +1950 | +900 |
| 25 | FXBZ-±800/530(550) | ±800 | 530(550) | 32 | 11500±50 | 11000 | 11000 | +3600 | +1950 | +900 |
| 26 | FXBZ-±800/160(180)-S | ±800 | 160(180) | 20 | 11500±50 | 10770 | 10770 | +3600 | +1950 | +900 |
| 27 | FXBZ-±800/210(240)-S | ±800 | 210(240) | 20 | 11500±50 | 10770 | 10770 | +3600 | +1950 | +900 |
| 28 | FXBZ-±800/300-S | ±800 | 300 | 24 | 11500±50 | 10690 | 10690 | +3600 | +1950 | +900 |
| 29 | FXBZ-±800/400(420)-S | ±800 | 400(420) | 28 | 11500±50 | 10610 | 10610 | +3600 | +1950 | +900 |
| 30 | FXBZ-±800/530(550)-S | ±800 | 530(550) | 32 | 11500±50 | 10420 | 10420 | +3600 | +1950 | +900 |
| Remarks: "S" for double section | ||||||||||
Note:
1. Different strength and coupling fittings are customizable based on specific needs.
2. Electrical data below 220kV is presented for composite line post insulators without corona rings and mounted vertically. For 220kV and above, Wuhan Line Power recommends the installation of corona rings.
3. Additional section lengths and creepage distances can be provided. Please contact the sales agency for detailed information.
4. All dimensions, tolerances, and tests adhere to allowable IEC standards or ANSI standards.
5. Dimensions are presented in millimeters (mm). Specify inches and pounds if required.
6. Tailored designs are available to meet the unique requirements of end-users. Contact us for personalized solutions.
Products Features
1. The silicone rubber housing of the Composite Line Post Insulator is formed through a complete injection molding process. It exhibits excellent hydrophobicity, hydrophobicity migration, and soil resistance. The insulator also boasts outstanding electrical insulation properties and aging resistance, effectively preventing pollution flashover accidents and ensuring the safe operation of high voltage transmission lines.
2. The modified ECR fiberglass reinforced epoxy resin rod is utilized for its resistance to high temperature, stress corrosion, acid attacks, damping action, high tensile strength (> 1200Mpa), and resistance to creep and fatigue failure. These properties guarantee the internal insulation quality and mechanical strength of the insulators.
3. End fittings are crimped onto the fiberglass rod using a voice-operated displacement-type crimper. This crimping technique ensures high mechanical strength and minimal dispersion. Employing the most advanced automatic overall injection molding technique and crimping connection method during production and assembly, the entire crimping process is computer-controlled, and the result is monitored by an ultrasonic detector to ensure each product meets the required standards.
Company Profile
Wuhan Line Power Transmission Equipment Co., Ltd. specializes in the research, development, production, and sales of high-voltage transmission power composite insulator series products. Our core technology is derived from esteemed scientific and research institutions, including Wuhan University (formerly Wuhan University of Water and Electricity), Hubei Institute of Chemical and Industry, and Wuhan High-Pressure Research Institution, among others.
Hot Tags: 400kv 500kv 660kv 800kv dc composite long rod insulator, China, manufacturers, suppliers, factory, wholesale, for sale